Part No
|
Description
|
|
|
7J0-8022 |
Z-2000 220V |
|
7J0-8023 |
Z-2000 230V
Tandem Type Atomic Absorption Spectrophotometer |
|
7J0-8024 |
Z-2000 240V |
|
7J0-8322 |
Z-2300 220V |
|
7J0-8323 |
Z-2300 230V
Flame Atomic Absorption Spectrophotometer |
|
7J0-8324 |
Z-2300 240V |
|
7J0-8722 |
Z-2700 220V |
|
7J0-8723 |
Z-2700 230V
Graphite Furnace Atomic Absorption Spectrophotometer |
|
7J0-8724 |
Z-2700 240V |
|
7J0-8812 |
SSC-110 FLAME AUTO SAMPLER, 220V |
|
7J0-8813 |
SSC-110 FLAME AUTO SAMPLER, 230V
Having a random access function, this autosampler can handle desired solution samples automatically to shorten the total measurement time. Also it minimizes consumption of samples. Up to 80 samples can be accommodated. The random access function can be set for each element. Automatic multi-element measurement can be performed for up to 12 elements. On completion of measurement, the burner chamber is washed and then the flame is turned of automatically. |
|
7J0-8814 |
SSC-110 FLAME AUTO SAMPLER, 240V |
|
7J0-8822 |
HFS-3, 220V |
|
7J0-8823 |
HFS-3, 230V |
|
7J0-8824 |
HFS-3, 240V |
|
7J0-8853 |
ONE SLOT BURNER (STD. BURNER) |
|
7J0-8855 |
HIGH SALT BURNER HEAD |
|
7J0-8857 |
HIGH TEMPERATURE BURNER
Applicable to the measurement of elements having a high dissociation energy, such as Al, B, Be, Ge, La, Nb, Si, Ta, Ti, V, W and Zr. Use this burner head in analyses with nitrogen dioxide - acetylene flame. |
|
7J0-8860 |
HEATED QUARTZ CELL WITH SUPPORT |
|
7J0-8861 |
HEATED QUARTZ CELL WITHOUT SUPPORT |
|
180-0451 |
MERCURY CELL WITH SUPPORT |
|
180-0450 |
MERCURY ANALYZER
Mercury is evaporated by adding reductant to a sample solution, thereby ensuring high accuracy in analyses. As a reaction reagent, SnCl_ is used. |
|
180-0410 |
MICRO SAMPLING KIT
Flame measurement can be made for a sample of less than 0.5ml. This accessory kit prevents the burner slot from being clogged by sample solution. |
|
7J0-8851 |
ALTERNATE GAS ACC.
Using this unit, you can use an alternate gas such as Ar-O_ mixture. This approach is advantageous in the analyses of a sample containing organic substances. |
|
7J0-8885 |
GRAPHITE TUBE HR(10PCE/SET)
Element analyses with low vapour pressure to 2,800ºC to 50_L, 10 pieces/pack |
|
172-8805 |
RING SET (4PCS/SET)
Ring for mounting cuvette on electrode part, 4 pieces/pack |
|
7J0-8890 |
CUP TYPE CUVETTE HR(10PCS/SET)
Element analyses with high vapour pressure to 2,100ºC to 50_L, 10 pieces/pack |
|
7J0-8880 |
PYROLITIC TUBE HR(10PCS/SET)
Element analyses with high vapour pressure to 2,800ºC to 100_L, 10 pieces/pack |
|
7J0-8895 |
PLATFORM TYPE CUVETTE HR(10PCS/SET) |
|
|
For reduction in matrix to 2,600ºC to 40_L, 10 pieces/pack |
|
190-6008 |
PLATFORM (10PCS/SET) |
|
208-0117 |
GLASS ATOMIZER SET (508-0161 REQUIRED)
Suitable for analyses of a sample solution containing acid that will dissolve metal. Even for a sample containing aqua regia, measurement can be made without corrosion. |
|
508-0146 |
PT ATOMIZER SET |
|
172-1635 |
DISPERSER |
|
139-0413 |
CLEANING WIRE SET (10PCS/SET) |
|
7J0-8863 |
NOZZLE |
|
207-0160 |
CAPILLARY TUBE SET (5PCS/SET) |
|
170-0263 |
CAPILLARY TUBE FOR ORGANIC SOLVENT (2PCS/SET) |
|
7J0-8867 |
EXHAUST PIPE (FOR GA) |